3 Phase Changeover Switch
3 phase changeover switch Suitable for AC 50HZ, rated voltage 400V/690V, rated current 1600A. 3 poles & 4 poles, It is widely used in power generation system.
- Product Details
- Parameter
- Product Acessories
- Download
-
3 phase changeover switch Suitable for AC 50HZ, rated voltage 400V/690V, rated current 1600A. 3 poles & 4 poles, It is widely used in power generation system.
The Terminal Is Copper T3
3-poles or 4-poles
Avoid erroneous operations
Designed according to IEC/ EN 60974-3
Conventional Current 250A 630A 1600A 3150A Rated Current In (A) 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150 Rated Insulation Voltage Ui (V) 1000 Dielectric Strength (V) 8000 10000 Rated Surge-Resistant Voltage Uimp KV Rated Working Current AC-21B 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150 380V AC-22B 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150 AC-23B 200 250 315 400 500 630 AC-21B 200 250 315 400 1000 1000 1600 2000 2500 2500 660V AC-22B 160 160 315 315 315 315 800 800 800 1000 1250 1600 AC-23B 100 125 Motor Power 380V 100 132 160 220 280 315 560 560 560 710 710 710 P (Kw) 660V 90 110 185 185 185 185 475 475 475 750 750 750 3 phase changeover switch is suitable for dual power supply of key loads such as fire fighting in construction field. EPS is suitable for EPS, which aims at solving first-class load power supply equipment such as emergency lighting, accident lighting, fire fighting facilities and so on. It provides an emergency power supply system with independent circuit in accordance with fire protection regulations. UPS mainly provides electricity for IT industry equipment, providing pure and uninterrupted backup power supply. Diesel generator power supply mode is suitable for use in electric field which needs long backup power supply, in conjunction with ATS, EPS and UPS.
Upon sensing the loss of normal or street power, the ATS logic signals the emergency engine or turbine generator system to start. When the emergency source of power is available at the ATS, the control logic samples the source to ensure critical parameters are within proper tolerance. At this point, the ATS will transfer to the emergency power supply.
These steps are reversed upon the return of the normal power source. The ATS logic will again verify the street power is within the desired parameters and stable prior to retransfer. Once the ATS is back in the normal position, the ATS logic dictates a cool down period for the emergency power system. Note that most set points and timing functions are adjusted to the customer’s requirements.